MEDUPI POWER PLANT SOUTH AFRICA - PDRT TANKS 4401A & 4401B
PROJECT PROFILEClient: Primary Containment
Distributor: Nukote Coating Systems
Applicator: BKV Holding
System: Nukote HLT, Nukote Chemshield TS
Location: Lephalale/South Africa
Description:
Demineraliazed water was entering the 2 numbers of PDRT tanks at maximum 95 degrees C. The floor / base substrate was concrete. The vertical walls where coating were terminated is Stainless Steel.
Nukote HLT, Nukote Chemshield TS 500 microns thick, Geo-Textile membrane, Hilti Fixing System, Nukote ST 4 mm thick and Nukote Chemshield TS 500 microns thick applied as per the method statement.